Contents: 2024 | 2023 | 2022 | 2021 | 2020 | 2019 | 2018 | 2017 | 2016 | 2015 | 2014 | 2013 | 2012 | 2011 | 2010 | 2009 | 2008 | 2007 | 2006 | 2005 | 2004 | 2003 | 2002 | 2001

2008, 11

S. Reuka

Acoustic field in a liquid wave-guide with impedance boundary conditions

language: Russian

received 15.04.2008, published 30.04.2008

Download article (PDF, 913 kb, ZIP), use browser command "Save Target As..."
To read this document you need Adobe Acrobat © Reader software, which is simple to use and available at no cost. Use version 4.0 or higher. You can download software from Adobe site (http://www.adobe.com/).

ABSTRACT

Experimental research of an acoustic field of ultrasonic impulse in a liquid wave-guide with realistic (impedance) boundary conditions is presented. Distribution of velocity amplitude over cross-section of hydrowave guides with various diameter and lengths are shown. Impulse shapes in various points of wave guide cross-section are also presented. The results are compared with a field of impulse in the unbounded environment, and with data of numerical modelling.

Key words: ultrasound, ultrasonic impulse, stream waveguide.

9 pages, 19 figures

Сitation: S. Reuka. Acoustic field in a liquid wave-guide with impedance boundary conditions. Electronic Journal “Technical Acoustics”, http://www.ejta.org, 2008, 11.

REFERENCES

1. С. В. Реука. Особенности прохождения ультразвуковым импульсом гидроволновода с неоднородными граничными условиями. Электронный журнал «Техническая акустика», http://ejta.org, 2008, 5.
2. С. К. Паврос, С. В. Реука. Исследование распространения ультразвукового импульса в струйном неоднородном волноводе. Дефектоскопия, 2008, №3


 

Sergey Reuka is a post-graduate of electroacoustics and ultrasonic department at the Saint-Petersburg State Electrotechnical University, leading expert at US-Constanta Ltd. General scientific interests: guided waves, ultrasonic transducers.

e-mail: ayo(at)list.ru